RANGER 8980
DOWNLOADABLE CONTROL COMMUNICATOR
INSTALLATION MANUAL
TABLE OF CONTENTS
TABLE OF CONTENTS......................................................................................... 1
GENERAL DESCRIPTION ....................................................................................2
STANDARD AND OPTIONAL PARTS LIST..........................................................2
PARTS DIAGRAM.................................................................................................. 3
TERMINAL DRAWING AND SPECIAL NOTES .................................................... 4
TERMINAL & FUSE DESCRIPTION ....................................................................4
HOW TO PROGRAM THE RANGER 8980...........................................................6
KEYPAD PROGRAMMING EXAMPLES ............................................................... 7
PROGRAMMING PHONE NUMBERS & FORMATS .........................................8-9
COMMUNICATOR FORMAT SELECTION GUIDE............................................... 9
OPTIONAL PROGRAMMING INSTRUCTIONS.............................................10-22
AVAILABLE ZONE TYPES .................................................................................. 11
PROGRAMMING THE AUXILIARY OUTPUTS................................................... 17
DOWNLOAD PROGRAMMING INSTRUCTIONS............................................... 23
PROGRAMMING WORKSHEETS .................................................................24-26
LOCAL TELEPHONE COMPANY INTERFACE INFO ........................................27
SPECIFICATIONS & WARRANTY ..................................................................Back
CADDX CONTROLS, INC.
GLADEWATER, TEXAS
800-727-2339
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1

RANGER 8980 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS TABLE OF CONTENTS

Pagina 2

10 LOCATIONS 000-003: PROGRAMMING THE MASTER ARM/DISARM CODE Locations 000-003 contain master arm/disarm code (user number 1). Location 000 conta

Pagina 3 - PARTS DIAGRAM

11 LOCATIONS 078-085: PROGRAMMING THE ZONE TYPES Locations 078 through 085 contain a number identifying the characteristics of each of the 8 zones

Pagina 4

12 LOCATION 090-091: PROGRAMMING FOR AUXILIARY 2, [4] & [6] DOUBLE KEYPRESS The Ranger 8980 has the ability to report an Auxiliary 2 code and

Pagina 5

13 LOCATION 103: PROGRAMMING TO REPORT OPENINGS The Ranger 8980 has the ability to report an opening code each time the control is disarmed.

Pagina 6

14 LOCATION 120-121: PROGRAMMING TO REPORT AC POWER LOSS The Ranger 8980 has the ability to report an AC power failure code when AC power is lost

Pagina 7

15 LOCATION 130: ENABLING THE SWINGER SHUTDOWN Location 130 is used to enable the burglary zone swinger shutdown. The number programmed in this lo

Pagina 8

16 LOCATION 138: NO ARMING WITH A ZONE BYPASSED If a "1" is programmed in location 138, the Ranger 8980 will not arm with any zone bypa

Pagina 9

17 LOCATION 145-148: PROGRAMMING THE AUXILIARY OUTPUTS Four of the functions in the following table are available on terminals 1 thru 4. These out

Pagina 10

18 LOCATION 151: PROGRAMMING THE NUMBER OF RINGS TO ANSWER DOWNLOAD CALL Location 151 contains the number of rings the 8980 must detect before ans

Pagina 11

19 LOCATION 160: PROGRAMMING THE CLOCK, CURRENT MINUTES - TENS DIGIT Location 160 contains the current minutes - tens digit. The time is entered

Pagina 12

2 RANGER 8980 INSTALLATION MANUAL General Description The Caddx Ranger 8980 is a versatile 8 zone up/downloadable security control with a built

Pagina 13

20 LOCATION 168-171: PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES Locations 168-171 contain the complex, or "seed code" req

Pagina 14

21 LOCATION 175: PROGRAMMING ZONES 1,2,7, & 8 FOR NORMALLY CLOSED OPERATION ONLY Location 175 is used to program zones 1,2,7, & 8 for nor

Pagina 15

22 LOCATION 177: SPLIT REPORTING - PROGRAMMING AC POWER FAIL, LOW BATTERY, OPEN/CLOSE, AND MAINTENANCE OPEN/CLOSE TO REPORT

Pagina 16

23 THE FOLLOWING LOCATIONS ARE ACCESSIBLE ONLY THROUGH DOWNLOADING LOCATIONS 186-193: CONTROL PANEL ACCESS CODE Locations 186-193 contain the ei

Pagina 17

24 ARM/DISARM CODES 1-7 LOCATION PAGE DESCRIPTION DATA 1 DATA 2 DATA 3 DATA 4 DEFAULT 000-003 10 USER #1 ARM / DISARM CODE &

Pagina 18

25 LOCATION PAGE DESCRIPTION ZONE ID EVENT/EXT CODE DEFAULT 103 12 OPENING COMMUNICATOR CODE MAN NUMBER "0" DISABLED 104-1

Pagina 19

26 LOCATION PAGE DESCRIPTION DATA DEFAULT 157 18 PROGRAM CLOCK, CURRENT DAY OF MONTH - ONES DIGIT UNDEFINED 158 18 PROGRAM CLOCK, C

Pagina 20

27 LOCAL TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connecti

Pagina 21

SPECIFICATIONS OPERATING POWER 16.5 VAC 25 VA Transformer AUXILIARY POWER 12 VDC 500mA LOOP RESISTANCE 300 Ohms Maximum BUILT-

Pagina 22

3 PARTS DIAGRAM

Pagina 23 - ALARM HISTORY

4 TERMINAL DRAWING & SPECIAL NOTES

Pagina 24 - ARM/DISARM CODES 1-7

5 TERMINAL DESCRIPTION TERMINAL DESCRIPTION 1 Connect one side of zone 1 loop. The other side of loop to common terminal 2.

Pagina 25

6 HOW TO PROGRAM THE 8980 The Ranger 8980 can be placed into the "Program" mode by either of the following methods. 1. Enter the 4 di

Pagina 26

7 PROGRAMMING EXAMPLE - FIGURE 1 8950 PROGRAMMER - FIGURE 2

Pagina 27

8 PAGES 8 & 9 DESCRIBE ALL THE LOCATIONS WHICH MUST BE PROGRAMMED FOR THE RANGER 8980 TO FUNCTION AND REPORT TO A CENTRAL STATION. OTHER OPTIO

Pagina 28 - FIVE YEAR LIMITED WARRANTY

9 LOCATION 074: PROGRAMMING COMMUNICATOR FORMAT FOR THE SECONDARY TELEPHONE NUMBER Location 074 contains the communicator format for the secondar